    Don't change the max_bpc connector prop if mode=current. · 24ee6144
    manuel alfayate authored and Marius Vlad's avatar Marius Vlad committed
    As things are, even when mode=current is specified on the .ini file,
    a full modeset is needed (and done), which causes a very noticeable
    screen blinking. That is because setting the max_bpc on a connector
    needs full modesetting.
    The idea here is that if mode=current on the .ini, no modesetting
    should be done, so the current max_bpc is programmed into the
    connector.
    But if a custom max-bpc=... is specified, that will be used instead,
    even if mode=current on the .ini
    
    Fixes: wayland/weston#660
    
    
    
    Signed-off-by: default avatarvanfanel <redwindwanderer@gmail.com>
    (cherry picked from commit 3240ccc6)
    24ee6144