broadband-modem-cinterion: keep operator and mode
Currently when requesting a specific operator with --3gpp-register-in-operator=26201
and additionally set the allowed modes with --set-allowed-modes=4G
.
The previously set operator 26201 is overwritten due to the architecture of the AT+COPS
command (AT+COPS=,,,).
The same thing happens if the allowed mode is set first and then an operator is requested.
Also the cinterion plugins does not implement load_current_mode
which makes the device have a different 'current mode' state than MM after initialization and prevents setting the device's allowed mode in some cases -> Fixes #926 (closed)