anv: HIZ+CCS corruption due to incomplete ambiguate
Ambiguating the HiZ+CCS of a depth buffer with WM_HZ_OP
doesn't ambiguate the CCS portion (see !9112 (merged)). I believe this means that anv will have an invalid CCS after transitioning from the UNDEFINED
layout. iris seems to be safe.