Sennheiser GSX1200 device ID update
Summary
Related to merge request 257 (!257 (merged)), 90-pulseaudio.rules needs one additional line added.
ATTRS{idVendor}=="1395", ATTRS{idProduct}=="00a1", ENV{PULSE_PROFILE_SET}="sennheiser-gsx.conf"
There was a firmware update sometime last year for the GSX1000/GSX1200 that updated the USB device IDs. The GSX100 updated device ID is reflected, but not the GSX1200. If you happen to perform the firmware update, for instance via dualbooting to Windows, or using with a KVM to switch between a linux and Windows PC, it will "break" Pulseaudio's use of the device.
environment
Steps to reproduce
Perform firmware update via Sennheiser Update tool on Windows (updater available from Sennheiser's website if needed)
What is the current bug behavior?
Sennheiser GSX1200 with firmware update is not recognized
What is the expected correct behavior?
Sennheiser GSX1200 should be recognized the same as previous firmware version