Instructions with difference in PM field can actually be paired up if the one without PM doesn't do packing/unpacking and non-NOP packing/unpacking operations from PM instruction aren't added to the other without PM. total instructions in shared programs: 48209 -> 47460 (-1.55%) instructions in affected programs: 11688 -> 10939 (-6.41%) Signed-off-by: Boyan Ding <boyan.j.ding@gmail.com> Reviewed-by: Eric Anholt <eric@anholt.net>
8d3b92af