[CI][DRMTIP] igt@kms_plane_scaling@pipe-[abc]-scaler-with-rotation|igt@kms_rotation_crc@cursor-rotation-180 - dmesg-warn - *ERROR* Fault errors on pipe [ABC]: 0x00000080
@mupuf
Submitted by Martin Peres Assigned to Intel GFX Bugs mailing list
Link to original bug (#107761)
Description
https://intel-gfx-ci.01.org/tree/drm-tip/drmtip_90/fi-skl-iommu/igt@kms_plane_scaling@pipe-a-scaler-with-rotation.html
[ 182.540221] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000080
[ 182.540313] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000080
[ 182.607036] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000080
[ 182.607206] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000080
[ 182.673705] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000080
[ 182.673753] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000080
[ 182.740425] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000080
[ 182.740497] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000080
[ 183.407643] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000100
[ 183.407701] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000100
[ 183.474366] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000100
[ 183.474439] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000100
[ 183.541156] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000100
[ 183.541344] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe A: 0x00000100
https://intel-gfx-ci.01.org/tree/drm-tip/drmtip_94/fi-skl-iommu/igt@kms_plane_scaling@pipe-b-scaler-with-rotation.html
[ 206.838412] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000080
[ 206.838449] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000080
[ 206.905155] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000080
[ 206.905191] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000080
[ 206.971921] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000080
[ 206.971963] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000080
[ 207.038686] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000080
[ 207.038848] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000080
[ 207.705928] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000100
[ 207.706130] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000100
[ 207.772585] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000100
[ 207.772629] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000100
[ 207.839398] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000100
[ 207.839645] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe B: 0x00000100[ 20
https://intel-gfx-ci.01.org/tree/drm-tip/drmtip_94/fi-skl-iommu/igt@kms_plane_scaling@pipe-c-scaler-with-rotation.html
[ 49.775054] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000080
[ 49.775104] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000080
[ 49.775126] DMAR: DRHD: handling fault status reg 3
[ 49.775192] DMAR: [DMA Read] Request device [00:02.0] fault addr 0 [fault reason 06] PTE Read access is not set
[ 49.841822] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000080
[ 49.842006] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000080
[ 49.842089] DMAR: DRHD: handling fault status reg 3
[ 49.842140] DMAR: [DMA Read] Request device [00:02.0] fault addr 0 [fault reason 06] PTE Read access is not set
[ 49.908571] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000080
[ 49.908758] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000080
[ 49.908844] DMAR: DRHD: handling fault status reg 3
[ 49.908897] DMAR: [DMA Read] Request device [00:02.0] fault addr 0 [fault reason 06] PTE Read access is not set
[ 49.975286] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000080
[ 49.975476] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000080
[ 49.975563] DMAR: DRHD: handling fault status reg 3
[ 50.642477] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000100
[ 50.642628] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000100
[ 50.709230] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000100
[ 50.709419] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000100
[ 50.775954] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000100
[ 50.776159] [drm:gen8_de_irq_handler [i915]] ERROR Fault errors on pipe C: 0x00000100